The system can automatically convert most of the data types from your message. The following types are possible:

CodeTypeLength (byte)
ucharunsigned char1
charsigned char1
usintunsigned short int2
sint    signed short int2
uint    unsigned int4
intsigned int4
float   floating point number 4
charsreturn char arrayLength of message
stringread and convert the message into HEX string formatLength of message * 2

IMPORTANT: By default, all data are represented in Little Endian format, typical for embedded devices. If you want to represent data in Big Endian format, add “be” before the data type.

Example

reading integer from devices message

  • In little endian format            int (or C3896.leint)